FCC 47 CFR PART 15 SUBPART C CERTIFICATION TEST REPORT FOR LTE Watch + BLUETOOTH and WLAN 2.4GHz b/g/n & NFC MODEL NUMBER: LG-W200V, LGW200V, W200V, LG-W200VW, LGW200VW, W200VW FCC ID: ZNFW200V REPORT NUMBER: 15I21799-E5V1 ISSUE DATE: SEPTEMBER 24, 2015 Prepared for LG ELECTRONICS MOBILECOMM U.S.A., INC 1000 SYLVAN AVENUE ENGLEWOOD CLIFFS, NEW JERSEY, 07632, U.S.A Prepared by UL VERIFICATION SERVICES INC. 47173 BENICIA STREET FREMONT, CA 94538, U.S.A. TEL: (510) 771-1000 FAX: (510) 661-0888 REPORT NO: 15I21799-E5V1 DATE: SEPTEMBER 28, 2015 MODEL NUMBER: LG-W200V, LGW200V, W200V, LG-W200VW, LGW200VW, W200VW FCC ID: ZNFW200V Revision History Rev. V1 Issue Date Revisions 09/28/15 Initial Issue Revised By Page 2 of 25 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. REPORT NO: 15I21799-E5V1 DATE: SEPTEMBER 28, 2015 MODEL NUMBER: LG-W200V, LGW200V, W200V, LG-W200VW, LGW200VW, W200VW FCC ID: ZNFW200V TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ......................................................................................... 4 2. TEST METHODOLOGY ............................................................................................................. 6 3. FACILITIES AND ACCREDITATION ......................................................................................... 6 4. CALIBRATION AND UNCERTAINTY ........................................................................................ 6 4.1. MEASURING INSTRUMENT CALIBRATION ...................................................................... 6 4.2. SAMPLE CALCULATION .................................................................................................... 6 4.3. MEASUREMENT UNCERTAINTY ....................................................................................... 6 5. EQUIPMENT UNDER TEST ....................................................................................................... 7 5.1. DESCRIPTION OF EUT ...................................................................................................... 7 5.2. MAXIMUM OUTPUT POWER.............................................................................................. 7 5.3. WORST-CASE CONFIGURATION AND MODE .................................................................. 7 5.4. MODIFICATIONS ................................................................................................................ 7 5.5. DESCRIPTION OF TEST SETUP ........................................................................................ 8 6. TEST AND MEASUREMENT EQUIPMENT ............................................................................. 11 7. RADIATED EMISSION TEST RESULTS.................................................................................. 12 7.1. LIMITS AND PROCEDURE ............................................................................................... 12 7.1.1. FUNDAMENTAL AND SPURIOUS EMISSIONS (0.15 – 30 MHz) .............................. 14 7.1.2. TX SPURIOUS EMISSION 30 TO 1000 MHz ............................................................. 15 8. AC MAINS LINE CONDUCTED EMISSIONS ........................................................................... 17 9. FREQUENCY STABILITY ........................................................................................................ 20 10. SETUP PHOTOS .................................................................................................................. 21 Page 3 of 25 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. REPORT NO: 15I21799-E5V1 DATE: SEPTEMBER 28, 2015 MODEL NUMBER: LG-W200V, LGW200V, W200V, LG-W200VW, LGW200VW, W200VW FCC ID: ZNFW200V 1. ATTESTATION OF TEST RESULTS COMPANY NAME: LG ELECTRONICS MOBILECOMM U.S.A., INC. EUT DESCRIPTION: LTE Watch + Bluetooth and WLAN 2.4GHz b/g/n & NFC MODEL: LG-W200V, LGW200V, W200V, LG-W200VW, LGW200VW, W200VW SERIAL NUMBER: 509KPZK000181 (conducted), 509KPCA000179 (radiated) DATE TESTED: SEPTEMBER 23 – 24, 2015 APPLICABLE STANDARDS STANDARD TEST RESULTS FCC PART 15 SUBPART C Pass UL Verification Services Inc. tested the above equipment in accordance with the requirements set forth in the above standards. All indications of Pass/Fail in this report are opinions expressed by UL Verification Services Inc. based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into account and are published for informational purposes only. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Note: The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. This document may not be altered or revised in any way unless done so by UL Verification Services Inc. and all revisions are duly noted in the revisions section. Any alteration of this document not carried out by UL Verification Services Inc. will constitute fraud and shall nullify the document. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, any agency of the Federal Government, or any agency of any government. Page 4 of 25 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. REPORT NO: 15I21799-E5V1 DATE: SEPTEMBER 28, 2015 MODEL NUMBER: LG-W200V, LGW200V, W200V, LG-W200VW, LGW200VW, W200VW FCC ID: ZNFW200V Approved & Released For UL Verification Services Inc. By: Tested By: VIEN TRAN CONSUMER TECHNOLOGY DIVISION WiSE SENIOR ENGINEER UL VERIFICATION SERVICES INC ROLLY ALEGRE CONSUMER TECHNOLOGY DIVISION WiSE LAB EMC TECHNICIAN UL VERIFICATION SERVICES INC DAN CORONIA CONSUMER TECHNOLOGY DIVISION WiSE PROJECT LEAD UL VERIFICATION SERVICES INC Page 5 of 25 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. REPORT NO: 15I21799-E5V1 DATE: SEPTEMBER 28, 2015 MODEL NUMBER: LG-W200V, LGW200V, W200V, LG-W200VW, LGW200VW, W200VW FCC ID: ZNFW200V 2. TEST METHODOLOGY The tests documented in this report were performed in accordance with ANSI C63.4-2009, FCC CFR 47 Part 2, FCC CFR 47 Part 15, RSS-GEN Issue 3, and RSS-210 Issue 8. 3. FACILITIES AND ACCREDITATION The test sites and measurement facilities used to collect data are located at 47173 and 47266 Benicia Street, Fremont, California, USA. Line conducted emissions are measured only at the 47173 address. The following table identifies which facilities were utilized for radiated emission measurements documented in this report. Specific facilities are also identified in the test results sections. 47173 Benicia Street 47266 Benicia Street Chamber A(IC: 2324B-1) Chamber D(IC: 2324B-4) Chamber B(IC: 2324B-2) Chamber E(IC: 2324B-5) Chamber C(IC: 2324B-3) Chamber F(IC: 2324B-6) Chamber G(IC: 2324B-7) Chamber H(IC: 2324B-8) UL Verification Services Inc. is accredited by NVLAP, Laboratory Code 200065-0. The full scope of accreditation can be viewed at http://ts.nist.gov/standards/scopes/2000650.htm. 4. CALIBRATION AND UNCERTAINTY 4.1. MEASURING INSTRUMENT CALIBRATION The measuring equipment utilized to perform the tests documented in this report has been calibrated in accordance with the manufacturer's recommendations, and is traceable to recognized national standards. 4.2. SAMPLE CALCULATION Where relevant, the following sample calculation is provided: Field Strength (dBuV/m) = Measured Voltage (dBuV) + Antenna Factor (dB/m) + Cable Loss (dB) – Preamp Gain (dB) 36.5 dBuV + 18.7 dB/m + 0.6 dB – 26.9 dB = 28.9 dBuV/m 4.3. MEASUREMENT UNCERTAINTY Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the apparatus: PARAMETER Conducted Disturbance, 0.15 to 30 MHz Radiated Disturbance, 30 to 1000 MHz UNCERTAINTY 3.52 dB 4.94 dB Uncertainty figures are valid to a confidence level of 95%. Page 6 of 25 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. REPORT NO: 15I21799-E5V1 DATE: SEPTEMBER 28, 2015 MODEL NUMBER: LG-W200V, LGW200V, W200V, LG-W200VW, LGW200VW, W200VW FCC ID: ZNFW200V 5. EQUIPMENT UNDER TEST 5.1. DESCRIPTION OF EUT The EUT is a LTE Watch + Bluetooth and WLAN 2.4 GHz b/g/n & NFC. 5.2. MAXIMUM OUTPUT POWER The testing was performed at 1 meter. The transmitter maximum E-field at 30m distance is 21.73 dBuV/m which converts from the 1 meter data. 5.3. WORST-CASE CONFIGURATION AND MODE The NFC function was tested at its’ fundamental and only operational frequency of 13.56MHz. The fundamental of the EUT was investigated in three orthogonal orientations X, Y and Z. It was determined that the Z-orientation was the worst-case orientation; therefore all final radiated testing was performed with the EUT in the Z-orientation while generating continuous emissions. 5.4. MODIFICATIONS No modifications were made during testing. Page 7 of 25 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. REPORT NO: 15I21799-E5V1 DATE: SEPTEMBER 28, 2015 MODEL NUMBER: LG-W200V, LGW200V, W200V, LG-W200VW, LGW200VW, W200VW FCC ID: ZNFW200V 5.5. DESCRIPTION OF TEST SETUP SUPPORT EQUIPMENT Radiated Emissions Above 30 MHz, AC Line Conducted Emissions and Frequency Stability: Description Manufacturer AC Adapter LG Support Equipment List Model Serial Number MCS-02WR FCC ID RA471011271 N/A I/O CABLES Cable Port No # of identical ports DC Power 1 Audio I/O Cable List Connector Cable Type Type Cable Length Remarks (m) Mini-USB Mini-Jack 1.2m 1m Shielded Unshielded N/A N/A Radiated Emissions above 30 MHz, AC Line Conducted Emissions: TEST SETUP The EUT is a stand-alone device configured and tested in a worst-case setup. Page 8 of 25 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. REPORT NO: 15I21799-E5V1 DATE: SEPTEMBER 28, 2015 MODEL NUMBER: LG-W200V, LGW200V, W200V, LG-W200VW, LGW200VW, W200VW FCC ID: ZNFW200V SETUP DIAGRAM FOR TESTS Radiated Emissions Below 30 MHz: Page 9 of 25 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. REPORT NO: 15I21799-E5V1 DATE: SEPTEMBER 28, 2015 MODEL NUMBER: LG-W200V, LGW200V, W200V, LG-W200VW, LGW200VW, W200VW FCC ID: ZNFW200V Radiated Emissions Above 30 MHz, AC Line Conducted Emissions: Page 10 of 25 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. REPORT NO: 15I21799-E5V1 DATE: SEPTEMBER 28, 2015 MODEL NUMBER: LG-W200V, LGW200V, W200V, LG-W200VW, LGW200VW, W200VW FCC ID: ZNFW200V 6. TEST AND MEASUREMENT EQUIPMENT The following test and measurement equipment was utilized for the tests documented in this report: Description Spectrum Analyzer, 44 GHz Antenna, Loop, 30 MHz Antenna, Biconolog, 30MHz-1 GHz Preamplifier, 1300 MHz EMI Test Receiver, 30 MHz LISN, 30 MHz DMM Digital Thermometer Temperature Chamber Test Equipment List Manufacturer Model Agilent / HP E4446A EMCO Sunol Sciences Agilent / HP R&S FCC Fluke Tektronix CSZ 6502 JB1 8447D ESHS 20 50/250-25-2 77-11 DTM920 2PHS-8-3 Asset T123 C00593 T243 C00580 N02396 C00626 N02303 None T267 Cal Due 10/28/15 02/20/16 12/08/15 01/21/16 08/08/16 01/14/16 10/31/15 10/21/15 03/04/16 Page 11 of 25 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. REPORT NO: 15I21799-E5V1 DATE: SEPTEMBER 28, 2015 MODEL NUMBER: LG-W200V, LGW200V, W200V, LG-W200VW, LGW200VW, W200VW FCC ID: ZNFW200V 7. RADIATED EMISSION TEST RESULTS 7.1. LIMITS AND PROCEDURE LIMIT §15.225 (a) The field strength of any emissions within the band 13.553–13.567 MHz shall not exceed 15,848 microvolts/ meter at 30 meters. (b) Within the bands 13.410–13.553 MHz and 13.567–13.710 MHz, the field strength of any emissions shall not exceed 334 microvolts/meter at 30 meters. (c) Within the bands 13.110–13.410 MHz and 13.710–14.010 MHz the field strength of any emissions shall not exceed 106 microvolts/meter at 30 meters. (d) The field strength of any emissions appearing outside of the 13.110– 14.010 MHz and shall not exceed the general radiated emission limits in § 15.209 as follows: §15.209 (a) Except as provided elsewhere in this subpart, the emissions from an intentional radiator shall not exceed the field strength levels specified in the following table: Limits for radiated disturbance of an intentional radiator Frequency range (MHz) Limits (µV/m) Measurement Distance (m) 0.009 – 0.490 2400 / F (kHz) 300 0.490 – 1.705 24000 / F (kHz) 30 1.705 – 30.0 30 30 30 – 88 100** 88 - 216 150** 216 – 960 200** Above 960 500 ** Except as provided in paragraph (g), fundamental emissions from intentional radiators operating under this section shall not be located in the frequency bands 54-72 MHz, 76-88 MHz, 174-216 MHz or 470-806 MHz. However, operation within these frequency bands is permitted under other sections of this part, e.g. §§ 15.231 and 15.241. §15.209 (b) In the emission table above, the tighter limit applies at the band edges. Formula for converting the filed strength from uV/m to dBuV/m is: Limit (dBuV/m) = 20 log limit (uV/m) Page 12 of 25 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. REPORT NO: 15I21799-E5V1 DATE: SEPTEMBER 28, 2015 MODEL NUMBER: LG-W200V, LGW200V, W200V, LG-W200VW, LGW200VW, W200VW FCC ID: ZNFW200V In addition: §15.209 (d) The emission limits shown the above table are based on measurements employing a CISPR quasi-peak detector except for the frequency bands 9-90 kHz, 110-490 kHz and above 1000 MHz. Radiated emissions limits in these three bands are based on measurements employing an average detector. §15.209 (d) The provisions in §§ 15.225, measuring emissions at distances other than the distances specified in the above table, determining the frequency range over which radiated emissions are to be measured, and limiting peak emissions apply to all devices operated under this part. TEST PROCEDURE ANSI C63.4-2009 The EUT is an intentional radiator that incorporates a digital device. The highest fundamental frequency generated or used in the device is 13.56 MHz. The frequency range was investigated from 0.15 MHz to the 10th harmonic of the highest fundamental frequency, or 1000 MHz, whichever is greater (1000MHz) RESULTS No non-compliance noted: Page 13 of 25 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. REPORT NO: 15I21799-E5V1 DATE: SEPTEMBER 28, 2015 MODEL NUMBER: LG-W200V, LGW200V, W200V, LG-W200VW, LGW200VW, W200VW FCC ID: ZNFW200V 7.1.1. FUNDAMENTAL AND SPURIOUS EMISSIONS (0.15 – 30 MHz) FCC Part 15, Subpart B & C Frequency (MHz) 1 Meter Distance Measurement At Emissions Chamber LG 15I21799 (LG-W200V) Jude Semana 9/23/2015 Company: Project #: Model #: Tester: Date: PK (dBu/V) QP (dBu/V) AV (dBuV) AF dB/m Distance Distance (m) Correction (dB) PK Corrected Reading (dBuV/m) AV Corrected Reading (dBuV/m) QP Limit AV Limit PK Margin AV Margin (dBuV/m) (dBuV/m) (dB) (dB) Notes Loop Antenna Face On: Z-Position Fundamental Field Strength & Within Bands: 13.56 70.26 -10.56 13.454 45.23 -10.55 13.553 42.03 -10.56 13.567 44.70 -10.56 13.667 29.20 -10.57 13.348 28.03 -10.53 13.772 28.37 -10.58 -59.08 -59.08 -59.08 -59.08 -59.08 -59.08 -59.08 21.73 -3.31 -6.50 -3.83 -19.32 -20.52 -20.14 -------- 84.00 50.48 50.48 50.48 40.51 40.51 29.54 -------- -62.3 -53.8 -57.0 -54.3 -59.8 -61.0 -49.7 -------- Fundamental @ 30m Dist 13.41-13.553MHz Sprious @ 30m 13.41-13.553MHz Sprious @ 30m 13.567-13.710MHz Spurious @ 30m 13.567-13.710MHz Spurious @ 30m 13.110-13.410MHz Spurious @ 30m 13.710-14.010MHz Spurious @ 30m Loop Antenna Face Off: Z-Position Fundamental Field Strength & Within Bands: 13.56 54.30 -10.56 13.453 40.34 -10.55 13.553 40.09 -10.56 13.567 35.88 -10.56 13.665 20.45 -10.57 13.348 22.67 -10.53 13.772 19.87 -10.58 -59.08 -59.08 -59.08 -59.08 -59.08 -59.08 -59.08 5.77 -8.20 -8.44 -12.65 -28.07 -25.88 -28.64 -------- 84.00 50.48 50.48 50.48 40.51 40.51 29.54 -------- -78.2 -58.7 -58.9 -63.1 -68.6 -66.4 -58.2 -------- Fundamental @ 30m Dist 13.41-13.553MHz Sprious @ 30m 13.41-13.553MHz Sprious @ 30m 13.567-13.710MHz Spurious @ 30m 13.567-13.710MHz Spurious @ 30m 13.110-13.410MHz Spurious @ 30m 13.710-14.010MHz Spurious @ 30m Spurious Emissions 9kHz - 490kHz: 0.01 30.23 -0.1 25.34 -0.489 24.87 -- 18.7 10.5 10.21 -99.08 -99.08 -99.08 -50.15 -63.24 -64.01 -50.15 -63.24 -64.01 67.60 47.60 33.82 47.60 27.60 13.82 -117.8 -110.8 -97.8 -97.8 -90.8 -77.8 9kHz-10kHz Spurious @ 30m 10kHz-100kHz Spurious @ 30m 100kHz-489kHz Spurious @ 30m Spurious Emissions 490kHz - 30MHz: 0.49 20.34 -1 19.87 -1.499 22.55 -2.611 21.56 -6.275 20.58 -24.05 18.35 -- 10.21 10.3 10.28 10.22 10.2 9.49 -59.08 -59.08 -59.08 -59.08 -59.08 -59.08 -28.54 -28.91 -26.26 -27.31 -28.30 -31.24 ------- 33.80 27.60 24.09 29.54 29.54 29.54 -62.3 -56.5 -50.3 -56.8 -57.8 -60.8 ------- 489kHz-490kHz Spurious @ 30m 490kHz-1MHz Spurious @ 30m 1MHz-1.705MHz Spurious @ 30 m 1.705MHz-5MHz Spurious @ 30m 5-10MHz Spurious @ 30m 20-30MHz Spurious @ 30m * No more emissions were found up to 30MHz Note: The emission limits are based on measurements employing a CISPR quasi-peak detector except for the frequency bands 9–90 kHz, 110–490 kHz and above 10000Mhz. Radiated emission limits in these three bands are based on measurements employing an average detector. P.K. = Peak Q.P. = Quasi Peak Readings A.F. = Antenna factor Rev. 11.21.14 Page 14 of 25 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. REPORT NO: 15I21799-E5V1 DATE: SEPTEMBER 28, 2015 MODEL NUMBER: LG-W200V, LGW200V, W200V, LG-W200VW, LGW200VW, W200VW FCC ID: ZNFW200V 7.1.2. TX SPURIOUS EMISSION 30 TO 1000 MHz EMI PLOT Page 15 of 25 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. REPORT NO: 15I21799-E5V1 DATE: SEPTEMBER 28, 2015 MODEL NUMBER: LG-W200V, LGW200V, W200V, LG-W200VW, LGW200VW, W200VW FCC ID: ZNFW200V Radiated Emissions Marker Frequency (MHz) Meter Reading (dBuV) Det AF T185 (dB/m) Amp/Cbl (dB) Corrected Reading (dBuV/m) QPk Limit (dBuV/m) Margin (dB) Azimuth (Degs) Height (cm) Polarity 30.0425 39.775 67.7825 81.34 94.9188 94.94 40.04 42.75 46.71 52.28 45.62 50.65 PK PK PK PK PK PK 21.8 14.5 8.3 7.9 8.6 8.6 -27.3 -27.1 -26.7 -26.5 -26.4 -26.4 34.54 30.15 28.31 33.68 27.82 32.85 40 40 40 40 43.52 43.52 -5.46 -9.85 -11.69 -6.32 -15.7 -10.67 0-360 0-360 0-360 0-360 0-360 0-360 100 100 200 100 100 100 PK - Peak detector Page 16 of 25 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. REPORT NO: 15I21799-E5V1 DATE: SEPTEMBER 28, 2015 MODEL NUMBER: LG-W200V, LGW200V, W200V, LG-W200VW, LGW200VW, W200VW FCC ID: ZNFW200V 8. AC MAINS LINE CONDUCTED EMISSIONS LIMITS §15.207 (a) Except as shown in paragraphs (b) and (c) of this section, for an intentional radiator that is designed to be connected to the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency or frequencies, within the band 150 kHz to 30 MHz, shall not exceed the limits in the following table, as measured using a 50µH/50 ohms line impedance stabilization network (LISN). Compliance with the provisions of this paragraph shall be based on the measurement of the radio frequency voltage between each power line and ground at the power terminal. The lower limit applies at the band edges. Frequency range (MHz) 0.15 to 0.50 0.50 to 5 5 to 30 Limits (dBµV) Quasi-peak 66 to 56 56 60 Average 56 to 46 46 50 Notes: 1. The lower limit shall apply at the transition frequencies 2. The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50 MHz. TEST PROCEDURE ANSI C63.4-2009 RESULTS No non-compliance noted: Page 17 of 25 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. REPORT NO: 15I21799-E5V1 DATE: SEPTEMBER 28, 2015 MODEL NUMBER: LG-W200V, LGW200V, W200V, LG-W200VW, LGW200VW, W200VW FCC ID: ZNFW200V LINE 1 Range 1: Line-L1 .15 - 30MHz Marker Frequency (MHz) Meter Reading (dBuV) Det T24 IL L1 LC Cables 1&3 Corrected Reading dBuV CFR 47 Part 15 Class B QP Margin (dB) .1545 .1545 .375 .384 1.5405 1.5315 50.27 26.72 38.64 25.51 33.46 17.87 Pk Av Pk Av Pk Av 1.3 1.3 .4 .4 .2 .2 .1 .1 51.57 28.02 39.04 25.91 33.76 18.17 65.75 58.39 56 -14.18 -19.35 -22.24 CFR 47 Part 15 Class B Avg Margin (dB) 55.75 -27.73 48.19 -22.28 46 -27.83 Pk - Peak detector Av - Average detection Page 18 of 25 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. REPORT NO: 15I21799-E5V1 DATE: SEPTEMBER 28, 2015 MODEL NUMBER: LG-W200V, LGW200V, W200V, LG-W200VW, LGW200VW, W200VW FCC ID: ZNFW200V LINE 2 Range 2: Line-L2 .15 - 30MHz Marker Frequency (MHz) Meter Reading (dBuV) Det T24 IL L2 LC Cables 2&3 Corrected Reading dBuV CFR 47 Part 15 Class B QP Margin (dB) 10 11 12 .1545 .1545 .384 .3975 3.0165 3.0345 43.41 24.78 30.98 21 25.72 11.44 Pk Av Pk Av Pk Av 1.4 1.4 .5 .4 .2 .2 .1 .1 44.81 26.18 31.48 21.4 26.02 11.74 65.75 58.19 56 -20.94 -26.71 -29.98 CFR 47 Part 15 Class B Avg Margin (dB) 55.75 -29.57 47.91 -26.51 46 -34.26 Pk - Peak detector Av - Average detection Page 19 of 25 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. REPORT NO: 15I21799-E5V1 DATE: SEPTEMBER 28, 2015 MODEL NUMBER: LG-W200V, LGW200V, W200V, LG-W200VW, LGW200VW, W200VW FCC ID: ZNFW200V 9. FREQUENCY STABILITY LIMIT §15.225 (e) The frequency tolerance of the carrier signal shall be maintained within ±0.01% of the operating frequency, over a temperature variation of -20 degrees to +50 degrees C at normal supply voltage, and for a variation in the primary supply voltage from 85% to 115% of the rated supply voltage at a temperature of 20 degrees C. For battery operated equipment, the equipment tests shall be performed using a new battery. TEST PROCEDURE ANSI C63.4 Section 13 RESULTS No non-compliance noted. Reference Frequency: EUT Channel 13.560000 MHz @ 20ºC Lim it: ± 100 ppm = 1.356 kHz Pow er Supply Environm ent Frequency Deviation Measureed w ith Tim e Elapse (Vdc) Tem perature (ºC) (MHz) Delta (ppm ) Lim it (ppm ) 3.80 50 13.5599435 2.681 ± 100 3.80 40 13.5599475 2.383 ± 100 3.80 30 13.5599633 1.218 ± 100 3.80 20 13.5599798 0.000 ± 100 3.80 10 13.5600285 -3.590 ± 100 3.80 13.5600624 -6.090 ± 100 3.80 -10 13.5600799 -7.381 ± 100 3.80 -20 13.5600824 -7.565 ± 100 3.80 -30 13.5600653 -6.304 ± 100 End of volt 3.23 20 13.5600629 -6.127 ± 100 4.37 20 13.5600621 -6.068 ± 100 Page 20 of 25 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.